  • Troubleshooting Steps You Must Know for Circuit Breaker Trip Failure

    Troubleshooting Steps You Must Know for Circuit Breaker Trip Failure

    2025-11-12 13:45:15
    When dealing with a circuit breaker that fails to trip, the first step is to check the control voltage of the breaker. Ensure that the control power supply is functioning properly and that the voltage is within the specified range. At the same time, verify that the switchgear terminals are not loose...
  • Maintenance Tips for Ensuring the Safety of Vacuum Circuit Breakers

    Maintenance Tips for Ensuring the Safety of Vacuum Circuit Breakers

    2025-11-11 10:17:05
    Maintenance Tips for Ensuring the Safety of Vacuum Circuit BreakersTo ensure the safety and long-term reliability of vacuum circuit breakers, regular maintenance is indispensable. First, the insulation performance of the vacuum circuit breaker should be inspected periodically to prevent failures cau...
  • Causes and Repair Solutions for Loosened Guide Rail Connections

    Causes and Repair Solutions for Loosened Guide Rail Connections

    2025-11-08 09:33:58
    Loosened guide rail connections are usually caused by long-term load operation. Over time, the screws and nuts at the connection points may gradually loosen due to vibration or wear. In addition, failure to apply the correct torque during installation is also a major factor contributing to loosening...
  • Power Substation equippments loading

    Power Substation equippments loading

    2025-11-07 16:54:10
    Power Substation equippments loading
  • Causes and Maintenance Strategies for Controller Failures

    Causes and Maintenance Strategies for Controller Failures

    2025-11-07 09:27:01
    During operation, controllers may experience various types of malfunctions. The main causes include overload, poor grounding, oxidation of relay contacts, and external environmental influences. Overload can damage internal components of the controller, while poor grounding may affect signal transmis...
  • In-depth Analysis of the Asynchronous Operation of Grounding Switches

    In-depth Analysis of the Asynchronous Operation of Grounding Switches

    2025-11-05 13:19:16
    The asynchronous operation of grounding switches is a common issue in power systems, typically manifested as the failure of opening and closing actions to occur simultaneously. This phenomenon is usually closely related to the design of electrical equipment, its operating conditions, and the reliabi...
  • Detailed Explanation of Medium- and High-Voltage Electrical Equipment and Their Applications

    Detailed Explanation of Medium- and High-Voltage Electrical Equipment and Their Applications

    2025-11-03 09:54:04
    Medium- and high-voltage electrical equipment are widely used in power systems and mainly include high-voltage circuit breakers, transformers, instrument transformers, and insulators. High-voltage circuit breakers are used to control and protect power lines, enabling rapid interruption of fault curr...
  • Effective Measures to Prevent Condensation in Switchgear Cabinets

    Effective Measures to Prevent Condensation in Switchgear Cabinets

    2025-11-01 09:48:06
    To effectively prevent condensation in switchgear cabinets, multiple measures can be adopted. First, maintaining proper temperature and humidity levels is fundamental. Installing air-conditioning or dehumidifying equipment can help regulate the internal environment of the cabinet and reduce moisture...
  • Vacuum Circuit Breaker Fault Troubleshooting and Emergency Handling Guide

    Vacuum Circuit Breaker Fault Troubleshooting and Emergency Handling Guide

    2025-10-31 09:54:44
    During operation, vacuum circuit breakers may encounter various faults, and timely and effective troubleshooting is crucial.First, abnormal noises or vibrations are common issues — the internal components should be checked for looseness or wear.Second, if the vacuum circuit breaker fails to operate...
  • Analysis of Solutions for Guide Rail Oil Leakage Issues

    Analysis of Solutions for Guide Rail Oil Leakage Issues

    2025-10-30 10:05:15
    Guide rail oil leakage is one of the most common faults and requires a comprehensive approach for effective resolution.First, identify the source of the leakage—common causes include damaged seals or loose connections. In such cases, replace the sealing ring or reinforce the connection area.Second,...
  • Analysis of the Working Principle and Practical Applications of Electric Controllers

    Analysis of the Working Principle and Practical Applications of Electric Controllers

    2025-10-29 10:31:08
    An electric controller is a key component used to control and regulate electrical equipment. Its primary function is to control the flow of electric current by receiving command signals, thereby enabling automatic operation of the equipment. The internal structure of an electric controller typically...
  • مفهوم قواطع دوائر الفراغ

    مفهوم قواطع دوائر الفراغ

    2025-10-28 15:34:48
    أقاطع الدائرة الفراغية (VCB)هو نوع من المفاتيح الكهربائية المستخدمة في أنظمة الطاقة لفتح أو إغلاق الدوائر الكهربائية. وأبرز ما يميزه هو استخدامهالفراغ كوسيلة عازلة وتبريد القوس الكهربائي، مما يتيح العزل عالي الكفاءة وانقراض القوس.أثناء التشغيل، يحتوي قاطع الدائرة الكهربائية علىغرفة القوس. عندما يمر...
  • تعريف المفاتيح الكهربائية

    تعريف المفاتيح الكهربائية

    2025-10-27 15:37:22
    تعتبر المفاتيح الكهربائية مكونًا لا غنى عنه في أنظمة الطاقة، وتستخدم في المقام الأولالسيطرة على المعدات الكهربائية وحمايتها وعزلها. وتتراوح وظائفها من تمكين توصيل وفصل التيارات الكهربائية إلى ضمان حماية المعدات أثناء الأعطال ومنع تصاعد الحوادث.هناك أنواع عديدة من المفاتيح الكهربائية، بما في ذلكقواطع...
  • أخطاء التشويش الميكانيكية في المعدات ذات الجهد العالي

    أخطاء التشويش الميكانيكية في المعدات ذات الجهد العالي

    2025-10-26 15:39:29
    أثناء العملية،معدات الجهد العاليقد تواجهأخطاء التشويش الميكانيكيةيحدث عادةً بسبب التآكل الداخلي أو عدم كفاية التشحيم أو دخول أجسام غريبة. عندما يتم الكشف عن مثل هذا التشويش، يجب أن تكون المعدات أولااغلاق للتفتيش، وينبغي أن تكون المكونات المتضررةتنظيفها وتشحيمها. إذا لزم الأمر، يجب أن تكون الأجزاء ال...
  • مبدأ العمل الأساسي لمفتاح التأريض

    مبدأ العمل الأساسي لمفتاح التأريض

    2025-10-25 15:42:18
    المبدأ العمل الأساسي لمفتاح التأريضهو توصيل أو فصل المعدات الكهربائية عن الأرض بأمان عن طريق التحكم في نقطة التأريض داخل الدائرة. يتكون هيكلها عادة مناتصالات، أآلية القيادة، وجهاز تخزين الطاقة.أثناء التشغيل، جهاز تخزين الطاقة أولايخزن الطاقة في الربيعوآلية القيادة بعد ذلكيفتح أو يغلق جهات الاتصال بس...
  • Advantages and Application Value of Vacuum Circuit Breakers

    Advantages and Application Value of Vacuum Circuit Breakers

    2025-10-25 13:43:59
    Vacuum circuit breakers are widely used in power systems due to their excellent insulation performance and safety features. First, the vacuum environment effectively prevents the formation of electric arcs, thereby reducing the risks of electric shock and equipment damage. In addition, vacuum circui...
  • The Important Functions and Roles of Grounding Switches in Power Systems

    The Important Functions and Roles of Grounding Switches in Power Systems

    2025-10-24 16:48:02
    The grounding switch is an indispensable component in power systems, primarily designed to ensure equipment safety and system stability. By grounding the equipment, the grounding switch effectively prevents overvoltage and leakage currents from damaging electrical devices. In the event of a fault, t...
  • تحليل شامل للأنواع الشائعة من المفاتيح الكهربائية في أنظمة الطاقة

    تحليل شامل للأنواع الشائعة من المفاتيح الكهربائية في أنظمة الطاقة

    2025-10-23 15:56:25
    في أنظمة الطاقة،المفاتيح الكهربائيةيشمل في المقام الأولقواطع الدائرة، ومفاتيح الفصل، ومفاتيح التأريض، ومفاتيح التحميل. تلعب هذه الأجهزة أدور حاسمفي تشغيل وسلامة الشبكة الكهربائية.قواطع دوائريمكن أن يقطع الدائرة بسرعة في حالة حدوث خطأ، مما يحمي المعدات من التلف.افصل المفاتيحيتم استخدامها لتوصيل أو فص...
ما مجموعه 68 مقالة, يتم عرض كل صفحة:18 مقالة
اتصل بنا

الهاتف: +8613736779975

البريد الإلكتروني: sales@vcbbreaker.com

المياه: طريق 66، منطقة التنمية الاقتصادية المميزة، زيجي، الصين

حقوق الطبع والنشر ©  2025 Eberry Electric Group  جميع الحقوق محفوظة

خريطة الموقع

يستخدم هذا الموقع ملفات تعريف الارتباط لضمان حصولك على أفضل تجربة على موقعنا.

يقبل يرفض